OPERATIONS
All Hydropure pumps are self-priming and require no lubrication. As fluid enters the pump inlet, the centrifugal force of the rotating vanes transfers energy to the fluid being pumped. Once running, the by-pass valve can be adjusted to limit the pump's maximum operating pressure. A built-in filter of 100 microns is normally used to remove particulate contaminants. Models with "B" & "D" designation have integrated filters.
TECHNICAL FEATURES
- Easily accessible by-pass adjustment
- Threaded front plug prevents leakage and permits an easy maintenance
- Self lubricating internal parts for low starting torque
- Stainless steel / AISI 303 single piece rotor shaft to reduce wear and to increase life
- Reduced vibration
- Low noise level
|
TECHNICAL DATA
- Max. capacity = 200 GPH (760Lt/hr)
- Max. pressure = 250 PSI (18 bars)
- Max. self-priming = 6 feet of water (dry pump in standard condition)
- Max. media temperature = 120 F (on enquire = 195 F with special features)
STANDARD PUMP MATERIALS
Pump Body = brass or stainless steel / AISI 303 Stator, Flanges, Vanes = carbon graphite Main Gasket = carbon graphite + NBR (nitrilic rubber) Rotor Shaft = stainless steel / AISI 303 O-Ring Gasket = NBR (nitrilic rubber) By-pass Valve = polycarbonate or nylon 6.6 Clamp = stainless steel / AISI 303
OPTIONAL
- Motor coupling by V-band clamp or by drilled flange mount
- Pump body with or without built-in filter
- Viton main gasket
- Without or with by-pass in standard or balanced options. By-pass in brass, stainless steel, plastic
|